Search History
  • OVOWELL poultry-house cooling pad and exhaust fan ventilation system
  • OVOWELL poultry-house cooling pad and exhaust fan ventilation system

Poultry Cooling Pad and Exhaust Fan System

For poultry houses that need an evaporative cooling and negative-pressure ventilation route matched to local climate and house layout.

Best fitHouse climate-control projects where cooling pads, exhaust fans, inlets, water and controls must be designed together.
Choose byHouse size, bird load, wet-bulb conditions, airflow, static pressure, pad geometry, fan duty, power and drainage.
Send for reviewHouse drawings, local climate, target air speed and temperature, current fan layout, water, power, drainage and installation photos.
  • OVOWELL poultry-house cooling pad and exhaust fan ventilation system

Description

Poultry-House Climate Control

Poultry House Cooling and Ventilation by Design

The OVOWELL poultry cooling pad and exhaust fan system combines evaporative cooling surfaces with controlled air movement for poultry houses. A useful design starts with house dimensions, climate, bird density, target airflow, static pressure and the available power and water services. Final cooling performance depends on the complete air path and the site conditions, not on one pad or fan specification alone.

Air pathinlet, pad, house and exhaust route
Wet-bulbclimate boundary for evaporative cooling
Pad + fanmatched components in one airflow design
House-specificlayout, load and utility review

How Evaporative Cooling Works in a Poultry House

Water wets the pad media while exhaust fans draw outside air through the wetted surface. Part of the water evaporates, and the incoming air can become cooler and more humid before it enters the house. The useful result depends on the difference between dry-bulb and wet-bulb conditions, airflow, pad selection, house leakage and heat load.

Wetted Pad Surface

Pad depth, height, width, flute geometry and water distribution affect air resistance and contact time.

Negative-Pressure Airflow

Exhaust fans create the air path through the pad and across the house, subject to inlets, openings and leakage.

Climate Boundary

Dry-bulb temperature, wet-bulb temperature and humidity determine the available evaporative cooling margin.

Heat-Load Balance

Bird density, house structure, solar gain, equipment and target air speed all influence the required ventilation duty.

Select the Cooling Pad for the Airflow Route

The pad is not selected by a catalogue code alone. It must fit the air volume, pressure loss, available wall opening, water loop and service access of the house.

Pad geometry

Choose height, width, thickness and flute arrangement for the planned opening and air path.

Confirm the final panel dimensions, quantity and replacement format.

Water distribution

Provide a pump, basin, pipework and control route that wets the pad evenly without uncontrolled overflow.

Confirm water quality, filtration, bleed-off and cleaning access.

Frame and basin

Frame material and deep-water basin options are reviewed against corrosion exposure, wall construction and service access.

Confirm the approved material and connection details for the ordered system.

Air resistance

Pad thickness and wet condition add pressure loss to the system.

Match the pad selection to the fan duty and the house static-pressure target.

Match Exhaust Fans to the House Air Path

Exhaust fans complete the design. Fan type, opening size, shutter arrangement, motor, control and installation position must be reviewed with the pad and the house envelope.

Fan Type

Heavy-hammer, push-pull, shutter and other fan arrangements can be compared by duty, opening and maintenance needs.

Air Volume and Pressure

Use the required house airflow and static-pressure curve to select a fan combination; do not use a free-air catalogue figure alone.

Shutters and Protection

Review shutter movement, guards, weather exposure, dust control and access for cleaning and inspection.

Power and Controls

Confirm motor supply, speed control, staged operation, alarms and the connection to the house climate-control panel.

Lay Out the Pads, Fans and Air Inlets Together

1. Record the house

Measure house length, width, height, openings, insulation, roof shape and internal obstructions.

Note bird density, equipment heat sources and the intended operating season.

2. Define the air direction

Set the intended pad-inlet side, exhaust side, inlet control and air movement through the occupied zone.

Check for short-circuiting, dead zones and bypass air around the pad.

3. Calculate the duty

Review target airflow, air speed, static pressure, heat load and the local dry-bulb/wet-bulb range.

Use the selected fan curve and pad pressure loss to confirm the arrangement.

4. Check the utilities

Confirm electrical supply, water source, drainage, pump location, controls and service clearances.

Provide a maintenance route for pads, basins, pumps, shutters and fan guards.

5. Commission by season

Test staged fan operation, pad wetting, air inlets, sensors and alarms before the high-load period.

Record actual temperature, humidity, airflow and water behavior under site conditions.

Configure the System by Climate, Load and Control

The following checklist is the practical input set for a poultry-house cooling review. It is not a fixed performance promise.

  • Country, city and seasonal dry-bulb, wet-bulb and humidity conditions.
  • House length, width, height, orientation, insulation and available wall openings.
  • Bird type, maximum bird density, age range and internal heat sources.
  • Target air speed, airflow stages, static pressure and temperature-control strategy.
  • Pad height, width, depth, frame, basin, water quality and drain or bleed-off route.
  • Fan type, quantity, motor supply, speed control, shutters, guards and alarm interfaces.

Cooling performance and component service intervals are reviewed against the actual house, climate and maintenance plan; no universal temperature, efficiency or energy result should be assumed.

Maintenance and Operating Boundaries

Evaporative cooling depends on clean air paths, even water distribution and correctly staged fans.

Pad Care

Inspect for scale, dust, algae, damaged edges and uneven wetting. Clean or replace media according to the approved procedure.

Water Loop

Check pump, basin, filters, pipework, float or level controls, bleed-off and drainage before the cooling season.

Fan Service

Inspect blades, belts, bearings, shutters, guards, vibration and electrical connections with services isolated.

Climate Limits

High humidity, poor house sealing, insufficient airflow or inadequate drainage can reduce the useful result and require a revised operating plan.

The system supports poultry-house climate control; it does not by itself guarantee animal performance, disease prevention, welfare outcomes or a specified indoor temperature.

Frequently Asked Questions

Is this system intended for poultry houses or greenhouses?

The current OVOWELL page is being repositioned around poultry-house climate control. A final design should be matched to the house dimensions, bird load, climate and ventilation path.

How does a cooling pad lower incoming air temperature?

Water evaporates from the pad surface as air moves through it. The available cooling margin depends on dry-bulb and wet-bulb conditions, pad selection, airflow and house leakage.

Can I choose a fan from its free-air airflow rating?

No. Fan duty must be checked against the selected pad, static pressure, inlets, house resistance, shutters and the required airflow stages.

What cooling-pad dimensions are available?

Pad height, width, thickness and flute arrangement are selected from the approved model range and the wall opening. Send the house opening and target duty before choosing a panel size.

Does the system guarantee a fixed temperature reduction?

No. Temperature and humidity results depend on climate, house construction, heat load, airflow and operating settings. OVOWELL reviews the design conditions before quotation.

What water quality and drainage are needed?

Provide the water source, quality, filtration, basin, bleed-off, cleaning and drain route. Scale, dust and algae can change pad performance and maintenance intervals.

What should be sent for a climate-control review?

Send house drawings, local climate data, bird density, target air speed and temperature, current fan and inlet layout, power, water, drainage and photos of the installation area.

Poultry-House Climate Review

Request a Cooling Pad and Exhaust Fan Configuration

Send the house dimensions, climate data, bird load, target airflow, static pressure, pad openings, fan layout, power, water and drainage conditions. OVOWELL can review the air path and system interfaces before quotation.

Farm systems

Review other poultry-house climate and monitoring equipment.

Explore farm systems

Related equipment

Compare the radar level meter and rotary airlock valve for selected feed and material-handling projects.